Example 2: Temperature-Pressure Flash(Click on the images for a larger version)Calculate the vapour and liquid mole fractions if the pipeline temperature in Example 1 drops to 0°C Step 1: Reset the "Initial Conditions":
Step 2: "Execute Flash". Step 3: From the calculated "Data", read the vapour and liquid mole fractions as 0.980 and 0.020 respectively.
Step 4: Now find "Vapour and Liquid Flowrates" in the pipeline for an assumed gas flow rate of 5 MMSCFD by pressing on the "Rate Calc" button and entering 5 MMSCFD as the feed rate.
|
|||
| ||||
|
|
| Download | Order | Contact Us | Copyright © 2006 FlowPhase Inc. |